Speckle tracking accuracy enhancement by temporal super-resolution of three-dimensional echocardiography images
DOI: 10.4103/jmss.JMSS_26_20
Abstract
Keywords
Full Text:
PDFReferences
Alessandrini M, Heyde B, Queiros S, Cygan S, Zontak M, Somphone O, et al. Detailed evaluation of five 3D speckle tracking algorithms using synthetic echocardiographic recordings. IEEE Trans Med Imaging 2016;35:1915-26.
Crosby J, Amundsen BH, Hergum T, Remme EW, Langeland S, Torp H. 3-D speckle tracking for assessment of regional left ventricular function. Ultrasound Med Biol 2009;35:458-71.
Duan Q, Angelini ED, Herz SL. Ingrassia C, Costa KD, Holmes JW, et al. Region-based endocardium tracking on real-time three-dimensional ultrasound. Ultrasound Med Biol 2009;35:256-65.
Alessandrini M, Liebgott H, Barbosa D, Bernard O. Monogenic Phase Based Optical Flow Computation for Myocardial Motion Analysis in 3D Echocardiography. In: International Workshop on Statistical Atlases and Computational Models of the Heart. Berlin, Heidelberg: Springer; 2012. p. 159-68.
Horn BK, Schunck BG. Determining Optical Flow. In Techniques and Applications of Image Understanding. International Society for Optics and Photonics; 1981:281. p. 319-31.
Lucas BD, Kanade T. An Iterative Image Registration Technique with an Application to Stereo Vision; 1981.
Mukherjee R, Sprouse C, Pinheiro A, Abraham T, Burlina P. Computing myocardial motion in 4-dimensional echocardiography. Ultrasound Med Biol 2012;38:1284-97.
Heyde B, Alessandrini M, Hermans J, Barbosa D, Claus P, D'hooge J. Anatomical image registration using volume conservation to assess cardiac deformation from 3D ultrasound recordings. IEEE Trans Med Imaging 2016;35:501-11.
Heyde B, Bouchez S, Thieren S, Vandenheuvel M, Jasaityte R, Barbosa D, et al. Elastic image registration to quantify 3-D regional myocardial deformation from volumetric ultrasound: Experimental validation in an animal model. Ultrasound Med Biol 2013;39:1688-97.
Zhu Y, Papademetris X, Sinusas AJ, Duncan JS. A coupled deformable model for tracking myocardial borders from real-time echocardiography using an incompressibility constraint. Med Image Anal 2010;14:429-48.
Elen A, Choi HF, Loeckx D, Gao H, Claus P, Suetens P, et al. Three-dimensional cardiac strain estimation using spatio-temporal elastic registration of ultrasound images: A feasibility study. IEEE Trans Med Imaging 2008;27:1580-91.
Queiros S, Morais P, Barbosa D, Fonseca JC, Vilaca JL, D'Hooge J. MITT: Medical Image Tracking Toolbox. IEEE Trans Med Imaging 2018;37:2547-57.
Queirós S, Vilaça JL, Morais P, Fonseca JC, D'hooge J, Barbosa D. Fast left ventricle tracking using localized anatomical affine optical flow. Int J Numer Method Biomed Eng 2017;33:e2871.
Jalali M, Behnam H, Davoodi F, Shojaeifard M. Temporal super-resolution of 2D/3D echocardiography using cubic B-spline interpolation. Biomed Signal Process Control 2020;58:101868.
Briand T, Monasse P. Theory and practice of image B-spline interpolation. Image Process Line 2018;8:99-141.
Refbacks
- There are currently no refbacks.
https://e-rasaneh.ir/Certificate/22728
ISSN : 2228-7477