Automatic Evaluation of Crown Preparation Using Image Processing Techniques: A Substitute to Faculty Scoring in Dental Education
DOI: 10.4103/jmss.JMSS_5_20
Abstract
Background: This study presents a new and innovative experimental method, including software and its prerequisite instruments, to use image processing techniques for crown preparation analysis. Materials and Methods: A platform was designed and constructed to take images from artificial teeth in different angles and directions and to process and analyze them by the proposed method to evaluate the quality and quantity of crown preparation. For each tooth, two series of images were taken from the artificial teeth before and after preparation, and image series were registered by two semi-automated and automated methods to transform them into one coordinate system. Region of interest was segmented by user interaction, and tooth region was segmented by substeps such as transformation to hue, saturation, and value color space, edge detection, morphology operations, and contour extraction. Finally, the amount and angle of crown preparation were computed and compared with standard measures to evaluate the quality of crown preparation. The proposed method was applied to a local dataset collected from Isfahan University of Medical Sciences. Results: Difference between the angle of crown preparation computed by the proposed method and that of the experts showed a mean absolute error of 7.17. The correlation between the segmented regions by the proposed method and those of the experts was also evaluated by the Intersection over Union (IOU) criterion. The best and worst performances achieved in cases by IOU were 0.94 and 0.76, respectively. Finally, the segmentation results of the proposed method indicated an average IOU of 0.89 in all images. Conclusions: Students can use this method as an assessment tool in preclinical tooth preparation to compare their crown work with standard parameters.
Keywords
Full Text:
PDFReferences
Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. J Prosthet Dent 2003;90:31-41.
Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett S. Fundamentals of Fixed Prosthodontics. Vol. 194. Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Applied Dental Sciences: Quintessence Publishing Company; 1997.
Poggio CE, Ercoli C, Rispoli L, Maiorana C, Esposito M. Metal-free materials for fixed prosthodontic restorations. Cochrane Database Syst Rev 2017;12:CD009606.
Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007;18 Suppl 3:73-85.
. McLean JW, “The Science and Art of Dental Ceramics,” The Nature of Dental Ceramics and their Clinical Use, 1979: p. 79-82.
Rosenstiel SF, Land MF. Contemporary Fixed Prosthodontics-E-Book. Future university of egypt: Elsevier Health Sciences; 2005.
Dodge W, Weed RM, Baez RJ, Buchanan RN. The correlation of resistance and retention to convergence angle. In journal of dental research. Am Assoc Dent Res 1983;62:267.
Hovijitra S, Robinson F, Brehm T. The relationship between retention and convergence of full crowns when used as fixed partial denture retainers. J Indian Dent Assoc 1979;58:21-4.
Mack PJ. A theoretical and clinical investigation into the taper achieved on crown and inlay preparations. J Oral Rehabil 1980;7:255-65.
Goodacre CJ. Palladium-silver alloys: A review of the literature. J Prosthetic Dent 1989;62:34-7.
Al Amri MD, Sherfudhin HR, Habib SR. Effects of Evaluator's fatigue and level of expertise on the global and analytical evaluation of preclinical tooth preparation. J Prosthodont 2018;27:636-43.
Liu L, Li J, Yuan S, Wang T, Chu F, Lu X, et al. Evaluating the effectiveness of a preclinical practice of tooth preparation using digital training system: A randomised controlled trial. Eur J Dent Educ 2018;22:e679-86.
Sirona. Sirona prepCheck. Computer-Aided Training System: A Plus for Universities and Students; 2019. Available from: www.sirona.com/en/products/treatment-centers/prepcheck. [Last accessed on 2019 June 05].
Kunkel TC, Engelmeier RL, Shah NH. A comparison of crown preparation grading via PrepCheck versus grading by dental school instructors. Int J Comput Dent 2018;21:305-11.
Schepke U, van Wulfften Palthe ME, Meisberger EW, Kerdijk W, Cune MS, Blok B, et al. Digital assessment of a retentive full crown preparation – An evaluation of prepCheck in an undergraduate preclinical teaching environment. Eur J Dent Educ 2020;00:1-18. doi: 10.1111/eje.12516.
Renne WG, McGill ST, Mennito AS, Wolf BJ, Marlow NM, Shaftman S, et al. E4D compare software: An alternative to faculty grading in dental education. J Dent Educ 2013;77:168-75.
Callan RS, Haywood VB, Cooper JR, Furness AR, Looney SW. et al. The validity of using E4D compare's “% comparison” to assess crown preparations in preclinical dental education. J Dent Educ 2015;79:1445-51.
Kateeb ET, Kamal MS, Kadamani AM, Abu Hantash RO, Arqoub MM. Utilising an innovative digital software to grade pre-clinical crown preparation exercise. Eur J Dent Educ 2017;21:220-7.
Tiu J, Cheng E, Hung TC, Yu CC, Lin T, Schwass D, et al. Effectiveness of crown preparation assessment software as an educational tool in simulation clinic: A pilot study. J Dent Educ 2016;80:1004-11.
Bay H, Ess A, Tuytelaars T, Gool LV. Speeded-up robust features (SURF). Comput Vis Image Underst 2008;110:346-59.
Chernov V, Alander J, Bochko V. Integer-based accurate conversion between RGB and HSV color spaces. Comput Electr Eng 2015;46:328-37.
Shrivakshan G, Chandrasekar C. A comparison of various edge detection techniques used in image processing. Int J Comput Sci Issue (IJCSI) 2012;9:269.
Lee J, Haralick R, Shapiro L. Morphologic edge detection. IEEE J Robot Autom 1987;3:142-56.
Feil PH, Gatti JJ. Validation of a motor skills performance theory with applications for dental education. J Dent Educ 1993;57:628-33.
Fuller JL. The effects of training and criterion models on interjudge reliability. J Dent Educ 1972;36:19.
Sharaf AA, Abdel Aziz AM, El Meligy OA. Intra-and inter-examiner variability in evaluating preclinical pediatric dentistry operative procedures. J Dent Educ 2007;71:540-4.
Schiff AJ, Salvendy G, Root CM, Ferguson GW, Cunningham PR. Objective evaluation of quality in cavity preparations. J Dent Educ 1975;39:92-6.
Refbacks
- There are currently no refbacks.
https://e-rasaneh.ir/Certificate/22728
ISSN : 2228-7477