Evaluation of the Lung Dose in Three-dimensional Conformal Radiation Therapy of Left-Sided Breast Cancer: A Phantom Study

Mahsa Abdemanafi, Mohammad Bagher Tavakoli, Ali Akhavan, Iraj Abedi

DOI: 10.4103/jmss.JMSS_1_19

Abstract


Background: Three-dimensional 3D-CRT: conformal radiation therapy is a selective modality in many radiotherapy centers for the treatment of breast cancer. One of the most common side effects of this method is radiation lung injury. Considering such an injury, lung dose deserves to be studied in depth. Methods: Computed tomography scan of a node-positive left-sided breast cancer woman was used for generating a thorax phantom. Ten thermoluminescent dosimeters (TLDs) were distributed evenly in the left lung of the phantom, and the phantom was scanned. The optimal plan, including supraclavicular and tangential fields, was created by the treatment planning system (TPS). The results of TLD dose measurements at the selected points in the phantom were compared to TPS dose calculations. Results: Lung doses calculated by TPS are significantly different from those measured by the TLDs (P = 0.007). The minimum and maximum differences were -0.91% and 4.46%, respectively. TLDs that were on the inner margin of the lung and breast tissue showed higher dose differences than the TLDs in the lung. Conclusion: The results of this study showed that TPS generally overestimated doses compared to TLD measurements due to incorrect beam modeling caused by contaminated electrons in the lung.


Keywords


Left-sided breast cancer, lung dose, phantom, three-dimensional conformal radiation therapy

Full Text:

PDF

References


Overgaard M, Christensen JJ, Johansen H, Nybo-Rasmussen A, Brincker H, van der Kooy P, et al. Postmastectomy irradiation in high-risk breast cancer patients. Present status of the Danish Breast Cancer Cooperative Group trials. Acta Oncol 1988;27:707-14. Back to cited text no. 1

Bellon JR, Katz A, Taghian A. Radiation therapy for breast cancer. Hematol Oncol Clin North Am 2006;20:239-57, vii. Back to cited text no. 2

Darby SC, McGale P, Taylor CW, Peto R. Long-term mortality from heart disease and lung cancer after radiotherapy for early breast cancer: Prospective cohort study of about 300,000 women in US SEER cancer registries. Lancet Oncol 2005;6:557-65. Back to cited text no. 3

Freedman GM, Anderson PR, Li J, Eisenberg DF, Hanlon AL, Wang L, et al. Intensity modulated radiation therapy (IMRT) decreases acute skin toxicity for women receiving radiation for breast cancer. Am J Clin Oncol 2006;29:66-70. Back to cited text no. 4

Senthilkumar S. Design of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements. Int J Radiat Res 2014;12:179. Back to cited text no. 5

Xie X, Ouyang S, Wang H, Yang W, Jin H, Hu B, et al. Dosimetric comparison of left-sided whole breast irradiation with 3D-CRT, IP-IMRT and hybrid IMRT. Oncol Rep 2014;31:2195-205. Back to cited text no. 6

Prior P, Sparks I, Wilson J, Li X, White J. Use of three dimensional conformal radiation therapy (3DCRT) for node positive breast cancer does not result in excess lung and heart irradiation. Int J Rad Oncolo Biol Phys 2011;81:S805. Back to cited text no. 7

Mehta VK, Goffinet DR. Unsuspected abnormalities noted on CT treatment-planning scans obtained for breast and chest wall irradiation. Int J Radiat Oncol Biol Phys 2001;49:723-5. Back to cited text no. 8

Aznar MC, Duane FK, Darby SC, Wang Z, Taylor CW. Exposure of the lungs in breast cancer radiotherapy: A systematic review of lung doses published 2010-2015. Radiother Oncol 2018;126:148-54. Back to cited text no. 9

Borzone G, Moreno R, Urrea R, Meneses M, Oyarzún M, Lisboa C. Bleomycin-induced chronic lung damage does not resemble human idiopathic pulmonary fibrosis. Am J Respir Crit Care Med 2001;163:1648-53. Back to cited text no. 10

Lind PA, Gagliardi G, Wennberg B, Fornander T. A descriptive study of pulmonary complications after postoperative radiation therapy in node-positive stage II breast cancer. Acta Oncol 1997;36:509-15. Back to cited text no. 11

Herbert CE, Ebert MA, Joseph DJ. Feasible measurement errors when undertaking in vivo dosimetry during external beam radiotherapy of the breast. Med Dosim 2003;28:45-8. Back to cited text no. 12

Wong S, Back M, Tan PW, Lee KM, Baggarley S, Lu JJ. Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients? Med Dosim 2012;37:163-9. Back to cited text no. 13

Butson MJ, Elferink R, Cheung T, Yu PK, Stokes M, Quach KY, et al. Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method. Phys Med Biol 2000;45:N143-9. Back to cited text no. 14

Davidson SE, Ibbott GS, Prado KL, Dong L, Liao Z, Followill DS. Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom. Med Phys 2007;34:1850-7. Back to cited text no. 15

Goldstone K. Tissue substitutes in radiation dosimetry and measurement. In: ICRU Report 44, International Commission on Radiation Units and Measurements. USA: W.B. Saunders; 1990. Back to cited text no. 16

Kelly CA, Wang XY, Chu JC, Hartsell WF. Dose to contralateral breast: A comparison of four primary breast irradiation techniques. Int J Radiat Oncol Biol Phys 1996;34:727-32. Back to cited text no. 17

Corredor CE. Dose Analysis by Radiation Treatment Planning System (TPS) Software vs. Thermoluminescent Dosimeters Output; 2004. Back to cited text no. 18

White J, Tai A, Arthur D, Buchholz T, MacDonald S, Marks L, et al. Breast cancer atlas for radiation therapy planning: Consensus definitions. Book Breast Cancer Atlas for Radiation Therapy Planning. 2009;73:944-51. Back to cited text no. 19

Haciislamoglu E, Colak F, Canyilmaz E, Zengin AY, Yilmaz AH, Yoney A, et al. The choice of multi-beam IMRT for whole breast radiotherapy in early-stage right breast cancer. Springerplus 2016;5:688. Back to cited text no. 20

Mauch P, Ng A, Aleman B, Carde P, Constine L, Diehl V, et al. Report from the rockefellar foundation sponsored international workshop on reducing mortality and improving quality of life in long-term survivors of Hodgkin's disease: July 9-16, 2003, Bellagio, Italy. Eur J Haematol Suppl 2005;66:68-76. Back to cited text no. 21

Castro P, García-Vicente F, Mínguez C, Floriano A, Sevillano D, Pérez L, et al. Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration. J Appl Clin Med Phys 2008;9:2676. Back to cited text no. 22

International Atomic Energy Agency. 398. Absorbed dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed dose to Water. Vienna: International Atomic Energy Agency; 2000. Back to cited text no. 23

Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys 1999;26:1847-70. Back to cited text no. 24

McCullough EC, Krueger AM. Performance evaluation of computerized treatment planning systems for radiotherapy: External photon beams. Int J Radiat Oncol Biol Phys 1980;6:1599-605. Back to cited text no. 25

Van Dyk J, Barnett RB, Cygler JE, Shragge PC. Commissioning and quality assurance of treatment planning computers. Int J Radiat Oncol Biol Phys 1993;26:261-73. Back to cited text no. 26

Farhood B, Bahreyni Toossi MT, Soleymanifard S, Mortezazadeh T. Assessment of the accuracy of dose calculation in the build-up region of the tangential field of the breast for a radiotherapy treatment planning system. Contemp Oncol (Pozn) 2017;21:232-9. Back to cited text no. 27

Nikoofar A, Hoseinpour Z, Mahdavi SR, Hasanzadeh H, Tavirani MR. High-dose-rate 192Ir brachytherapy dose verification: A phantom study. Iran J Cancer Prev 2015;8:23-31. Back to cited text no. 28

Ottosson W, Andersen CE, Behrens CF. Improved radiotherapy for locally advanced non-small cell lung carcinoma (NSCLC) patients 2015;12:35-43. Back to cited text no. 29

Baird CT, Starkschall G, Liu HH, Buchholz TA, Hogstrom KR. Verification of tangential breast treatment dose calculations in a commercial 3D treatment planning system. J Appl Clin Med Phys 2001;2:73-84. Back to cited text no. 30

Zhao Y, Qi G, Yin G, Wang X, Wang P, Li J, et al. A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation. Radiat Oncol 2014;9:287. Back to cited text no. 31

Aljarrah K, Pawlickj T, Niemierko A. A clinical study of MLC-based IMTT lung dose calculation accuracy on plan evaluation parameters. J Cancer Sci Ther 2010;2:74. Back to cited text no. 32


Refbacks

  • There are currently no refbacks.


 

  https://e-rasaneh.ir/Certificate/22728

https://e-rasaneh.ir/

ISSN : 2228-7477