Designing an optimized novel femoral stem
DOI: 10.4103/jmss.JMSS_1_17
Abstract
Keywords
Full Text:
PDFReferences
Dreinhofer KE, Diepper P, Sturmer T, Grober-Gratz D, Floren M, Gunther KP, et al. Indications for total hip replacement: comparison of assessments of orthopaedic surgeons and referring physicians. Ann Rheum Dis 2006;65:1346-50.
Georgette FS. Prosthetic device with porous matrix and method of manufacture. US Patent, No. 5201766A; 1993.
Mai KT, Verioti CA, Casey K, Slesarenko Y, Romeo L, Colwell CW. Cementless femoral fixation in total hip arthroplasty. Am J Orthop 2010;39:126-30.
Todor A, Lucaciu D. Are proximally coated better than fully coated cementless stems for total hip replacement? A DXA study. Cj Med 2010;83:700-3.
EL-Sheikh HEF. Finite element simulation of hip joint replacement under static and dynamic loading. M. Sc. Thesis, Dublin City University; 2002.
Axelsson R, Trepte O. An osseointegration implant. European Patent, No. 1779812A1; 2006.
Ten Broeke RH, Tarala M, Arts JJ, Janssen DW, Verdonschot N, Geesink RG. Improving peri-prosthetic bone adaptation around cementless hip stems: a clinical and finite element study. Med Eng Phys 2014;36:345-53.
Krishna BV, Xue W, Bose S, Bandyopadhyay A. Engineered porous metals for implants. JOM 2008;60:45-8.
Barrak RL, Jasty M, Bragdon C, Haire T, Harris WH. Thigh pain despite bone ingrowth into uncemented femoral stems. J Bone Joint Surg Br 1992;74:507-10.
Zimmer AH, Zimmer, Inc. Fitmore hip stem. http://www.zimmer. com/content/pdf/en-GB/Fitmore_Hip_Stem_Brochure_06.01558. 012_10_2011 (April 8, 2014).
Tai C, Chen W, Lee MS, Lee P, Shih C. Comparison of stress shielding between straight and curved stems in cementless total hip arthroplasty-an in vitro experimental study. J Med Biol Eng 2004;24:177-81.
Collaghan JJ, Fulghum CS, Glisson RR, Stranne SK. The effect of femoral stem geometry on interface motion in uncemented porous coated total hip prostheses. Comparison of straight-stem and curved-stem designs. J Bone Joint Surg Am 1992;74:839-48.
McLaughlin JR, Lee KR. Uncemented total hip arthroplasty using a tapered femoral component in obese patients: an 18-27 year follow-up study. J Arthroplasty 2014;29:1365-8.
Van Oldenrijk J, Molleman J, Klaver M, Poolman RW, Haverkamp D. Revision rate after short term total hip arthroplasty. Acta Orthop 2014; 85: 250-8.
To th K, Soha r G. Short-stem hip arthroplasty. In: Kinove P, editor. Arthroplasty-Update. p. 143-57.
Reimeringer M, Nuño N, Desmarais-Trepanier C, Lavigne M, Vendittoli PA. The influence of femoral stem length and design on its primary stability: a finite element analysis. Comput Method Biomec 2013;16:1221-31.
Meding JB, Ritter MA, Keating EM, Faris PM. Comparison of collared and collarless femoral components in primary uncemented total hip arthroplasty. J Arthroplasty 1997;12:273-80.
OliveriaMV, PereiraLC,CairoAA. Porous structure characterization in titanium coating for surgical implant. Mat Res 2002;5:269-73.
Thelen S, Barthelat F, Brinson LC. Mechanics considerations for microporous titanium as an orthopedic implant material. J Biomed Master Res A 2004;69:601-10.
Phillips TW, Messieh SS, Mcdonald PD. Femoral stem fixation in hip replacement: a biomechanical comparison of cementless and cemented prosthesis. J Bone Joint Surg Br 1990;72:431-4.
Kienapfel H, Sprey C, Wilke A, Griss P. Implant fixation by bone ingrowth. J Arthroplasty 1999;14:355-68.
Altimed A. Hip joint endoprostheses. http://www.altimed.by/ uploads/userfiles/files/altimed_catalogue_2012_english.pdf (Nov. 11, 2014).
Dong NNG, Wang A, Jones E, Plaskon GE. Gradient porous implant. US Patent, No. 7578851B2; 2009.
Nietert M, Englisch N, Kreil P, Alba-Lopez G. Loads in hip disarticulation prostheses during normal daily use. Prosthet Orthotot Int 1998;22:199-215.
Refbacks
- There are currently no refbacks.
https://e-rasaneh.ir/Certificate/22728